283 research outputs found

    Mathematical modeling of chemically reactive pollutants in indoor air

    Get PDF
    A general mathematical model is presented for predicting the concentrations of chemically reactive compounds in indoor air. The model accounts for the effects of ventilation, filtration, heterogeneous removal, direct emission, and photolytic and thermal chemical reactions. The model is applied to the induction of photochemically reactive pollutants into a museum gallery, and the predicted NO, NO_x-NO, and O_3 concentrations are compared to measured data. The model predicts substantial production of several species due to chemical reaction, including HNO_2, HNO_3, NO_3, and N_2O_5. Circumstances in which homogeneous chemistry may assume particular importance are identified and include buildings with glass walls, indoor combustion sources, and direct emission of olefins

    Protection of Works of Art From Atmospheric Ozone

    Get PDF
    Assesses the colorfastness of organic colorants and watercolor pigments tested in atmospheric ozone. A summary of a full report of the Environmental Quality Laboratory, California Institute of Technology, Pasadena

    Investigating CO2 Removal by Ca- and Mg-based Sorbents with Application to Indoor Air Treatment

    Get PDF
    Indoor carbon dioxide (CO 2 ) levels serve as an indicator of ventilation sufficiency in relation to metabolic effluents. Recent evidence suggests that elevated CO 2 exposure (with or without other bioeffluents) may cause adverse cognitive effects. In shelter-in-place (SIP) facilities, indoor CO 2 levels may become particularly elevated. This study evaluates four low-cost alkaline earth metal oxides and hydroxides as CO 2 sorbents for potential use in indoor air cleaning applications. Sorbents studied were MgO, Mg(OH) 2 , Ca(OH) 2 and commercially available soda lime. Uncarbonated sorbents characterized with nitrogen adsorption porosimetry showed BET surface areas in the 5.6ā€“27 m 2 /g range. Microstructural analyses, including X-ray diffraction, thermogravimetric analysis and scanning electron microscopy confirmed the carbonation mechanisms and extent of sorption under environmental conditions typical of indoor spaces. Ca-based sorbents demonstrated higher extent of carbonation than Mg-based sorbents. Laboratory parameterizations, including rate constants ( k ) and carbonation yields ( y ), were applied in material balance models to assess the CO 2 removal potential of Ca-based sorbents in three types of indoor environments. Soda lime ( k = [2.2ā€“3.6] Ɨ 10 āˆ’3 m 3 mol CO 2 āˆ’1 h āˆ’1 , y = 0.49ā€“0.51) showed potential for effective use in SIP facilities. For example, CO 2 exposure in a modeled SIP facility could be reduced by 80% for an 8-h sheltering interval and to levels below 5000 ppm for an 8-h period with a practically sized air cleaner. Predicted effectiveness was more modest for bedrooms and classroom

    Airborne Particles in Museums

    Get PDF
    Presents one in a series of research activities aimed at a better understanding of the origin and fate of air pollution within the built environment

    Bioaerosol Deposition on an Air-Conditioning Cooling Coil

    Get PDF
    This study is concerned with the role of a fin-and-tube heat exchanger in modifying microbial indoor air quality. Specifically, depositional losses of ambient bioaerosols and particles onto dry (not cooled) and wet (cool) coil surfaces were measured for different airspeeds passing through the test coil. Total, bacterial and fungal DNA concentrations in condensate water produced by a wet coil were also quantified by means of fluorescent dsDNA-binding dye and qPCR assays. Results revealed that the deposition of bioaerosols and total particles is substantial on coil surfaces, especially when wet and cool. The average deposition fraction was 0.14 for total DNA, 0.18 for bacterial DNA and 0.22 for fungal DNA on the dry coil, increasing to 0.51 for total DNA, 0.50 for bacterial DNA and 0.68 for fungal DNA on the wet coil. Overall, as expected, deposition fractions increased with increasing particle size and increasing airspeed. Deposited DNA was removed from the cooling coil surfaces through the flow of condensing water at a rate comparable to the rate of direct deposition from air. A downward trend of bacterial and fungal DNA measured in condensate water over time provides suggestive evidence of biological growth on heat exchangers during nonoperational times of a ventilation system. This investigation provides new information about bioaerosol deposition onto a conventional fin-and-tube cooling coil, a potentially important factor influencing indoor exposure to microbial aerosols in air-conditioned buildings
    • ā€¦